How it works

What is an external gear pump?

A positive displacement pump in which two identical gears mesh side by side inside a close-fitting body. The fluid is carried from inlet to outlet in the spaces between the teeth and the body; where the teeth mesh, the fluid cannot pass back and is pushed out.

Why is it suited to viscous fluids?

It moves a fixed volume at every revolution. From medium-high viscosities upwards it is practically the obligatory choice: a centrifugal pump loses flow quickly as viscosity rises, a gear pump does not, and viscous fluids also seal the internal clearances.

Can it also pump thin fluids such as solvents?

Yes, gear pumps also handle thin fluids, even petrol. With thin and volatile fluids the real flow is more affected by discharge pressure, and seals and ATEX classification must be checked.

What is slip?

The small amount of fluid that flows back through the internal clearances from the discharge to the suction side. It grows with pressure and decreases with viscosity: it is why the real flow is partly affected by discharge pressure.

Flow and speed

How is the flow adjusted?

By varying the rotation speed, ideally with an inverter: displacement is fixed, so flow is proportional to speed. Our model tables give the flow at 450, 950 and 1,450 rpm.

Does the flow change with discharge pressure?

Partly. With viscous fluids the reduction is minimal; with thin and volatile fluids it is more significant, but not comparable to that of a centrifugal pump.

Can the pump meter an exact quantity?

The inverter lets the pump reach the desired instantaneous flow. Metering, that is delivering a precise quantity and stopping at the right moment, is done by the plant control system that drives the pump.

What speed should the pump run at?

It depends on the fluid: the more viscous or abrasive it is, the lower the speed. For very viscous products we choose a larger pump running slowly rather than a small one running fast.

Send us your fluid data: we reply within 24 hours with the right pump.

Installation

Is the pump self-priming?

Yes, it creates the vacuum needed to draw the fluid and can lift from a container below the pump. With viscous fluids priming improves further, because the fluid seals the clearances.

Can the pump run in reverse?

Yes, NAV, ZV and CR pumps are reversible: by inverting the rotation they pump in the opposite direction, useful for emptying lines back into the tank.

Can the pump run dry?

Only briefly, for example during priming. Gears and seal are lubricated by the fluid: prolonged dry running must be avoided.

How should the suction line be designed?

Short, straight and with a generous diameter, especially with viscous fluids; where possible with the pump under head. Avoid air entering through fittings.

Is a filter needed?

A strainer upstream protects the gears from foreign bodies. Its mesh and size are chosen so as not to restrict suction with viscous products.

What is cavitation?

The formation of vapour bubbles when the pressure at suction drops too low; it causes noise, loss of flow and wear. It is prevented with short, wide suction lines, lower speed and, for volatile fluids, adequate suction pressure.

Fluids and materials

Can fluids with fillers be pumped?

Yes, filled resins and quartz paints are pumped regularly, at low speed and with abrasion-resistant materials. Large solid particles are not suited to a gear pump.

Cast iron or stainless steel?

Cast iron for resins, solvent paints, polyols, plasticizers; AISI 316 stainless steel for aggressive fluids and products that must stay clean. See the materials guide.

How is a product that sets at room temperature pumped?

With a heated pump: thermal oil jacket (CR series), electric cartridges or hot spot. The pump must be at temperature before start-up.

Do you also build custom pumps?

Yes. If the right pump is not in the catalogue, we design and build it for your application.

Send us your fluid data: we reply within 24 hours with the right pump.

Certifications and supply

Are the pumps certified?

Our quality system is certified ISO 9001:2015 by SGS since 2004, and the pumps carry CE marking under the Machinery Directive 2006/42/EC.

Are ATEX pumps available?

Yes, with technical file archived with TÜV, for zones 1, 2, 21 and 22 and temperature classes T1 to T4. Tell us zone, temperature class and fluid.

Do you ship abroad?

Yes, the pumps are built in Bologna and shipped worldwide. Tell us your mains voltage and frequency (50 or 60 Hz) for the motor.

How do I identify my pump for a replacement?

Send us a photo of the nameplate and of the pump on WhatsApp, or attach it to the form: we find the equivalent model.

How quickly do you reply?

Within 24 hours, with recommended pump, configuration and price.

Related guides: how to choose the pump, pump heating, cast iron or stainless steel, shaft seals, atex pumps, pump selector, replace your pump.

Technical reply within 24 hours

Request a quote

Fill in the four required fields: our engineers in Bologna reply within 24 hours with the recommended pump, configuration and price. Technical details and the data sheet help, but are optional.

  • Made in Bologna since 1955
  • ISO 9001:2015 certified · ATEX available
  • Self-priming and reversible pumps
  • Technical reply within 24 hours
Add technical details (optional)

Technical reply within 24 hours. No obligation.

Quote WhatsApp